Part
# |
General
Description |
|
21
|
Float
type make-up water feeder for boiler receiver tanks. Direct mounting
into receiver tank eliminates the need for equalizing connections.
Proportional feed action. Maximum water supply pressure of 150
psi., and 35 psi operating pressure. Mounting flange is 5-3/4" diameter
with (6) 7/16" bolt holes. Tapped 3/4" female I.P supply.
|
|
25A
|
Float
type make-up water feeder for boiler receiver tanks. Proportional
feed action. Maximum water supply pressure of 100 psi., and 35
psi operating pressure. Tapped 3/4" female I.P supply and
1" female I.P. equalizing connections.
|
|
27W
|
Float
operated liquid level control for open tank applications. Valve
opens to full capacity with a small drop of the float. Supply
is 3/4" female I.P and 100 psi maximum pressure.
|
|
42N
|
Combination
float type low water cutoff & pump controller, with 1/2"IP
gauge glass connections for steam boilers. Automatic reset, (2)
120 volt mercury 2-wire single pole single throw switches for
low water cut-off and pump control. Maximum pressure is 50 psi.
Tapped 1" female IP.
|
|
42
|
Combination
float type low water cutoff & pump controller, for steam
boilers with a separate water column. Automatic reset, (2) 120
volt mercury 2-wire single pole single throw switches for low
water cut-off and pump control. Maximum pressure is 50 psi. Tapped
1" female IP.
|
|
42A
|
Combination
float type low water cutoff & pump controller, with quick
hook-up fittings for steam boilers. Automatic reset, (2) 120
volt mercury 2-wire single pole single throw switches for low
water cut-off and pump control. Maximum pressure is 50 psi. Tapped
1" female IP.
|
|
42S
|
Combination
float type low water cutoff & pump controller, for steam
boilers with a separate water column. Automatic reset, (2) 120
volt bi-metal 2-wire single pole single throw snap switches for
low water cut-off and pump control. Maximum pressure is 50 psi.
Tapped 1" female IP.
|
|
42S-A
|
Combination
float type low water cutoff & pump controller, with quick
hook-up fittings for steam boilers. Automatic reset, (2) 120
volt bi-metal 2-wire single pole single throw snap switches for
low water cut-off and pump control. Maximum pressure is 50 psi.
Tapped 1" female IP.
|
|
42S-N
|
Combination
float type low water cutoff & pump controller, with 1/2"IP
gauge glass connections for steam boilers. Automatic reset, (2)
120 volt bi-metal 2-wire single pole single throw snap switches
for low water cut-off and pump control. Maximum pressure is 50
psi. Tapped 1" female IP.
|
|
47-2M
|
Combination
float type low water cutoff & water feeder, with quick hook-up
connections for steam or hot water boilers. Manual reset on 120
volt number 2 cutoff switch, proportional feed action, continuous
maintenance of minimum safe water level independent of electrical
service. Maximum pressure is 150 psi water and 25 psi steam.
|
|
47
|
Combination
float type water feeder, with quick hook-up connections for steam
or hot water boilers. Proportional feed action, continuous maintenance
of minimum safe water level independent of electrical service.
Maximum pressure is 150 psi water and 25 psi steam.
|
|
47-2
|
Combination
float type low water cutoff & water feeder, with quick hook-up
connections for steam or hot water boilers. Automatic reset on
120 volt number 2 cutoff switch, proportional feed action, continuous
maintenance of minimum safe water level independent of electrical
service. Maximum pressure is 150 psi water and 25 psi steam.
|
|
51
|
Combination
float type water feeder, for low pressure steam or hot water
boilers larger than 5,000 square feet capacity. Continuous maintenance
of minimum safe water level independent of electrical service.
Maximum pressure is 150 psi water and 35 psi steam. Tapped 1" female
I.P.
|
|
51-2
|
Combination
float type low water cutoff & water feeder, for low pressure steam
or hot water boilers larger than 5,000 square feet capacity. Automatic
reset on 120 volt number 2 cutoff switch, continuous maintenance
of minimum safe water level independent of electrical service.
Maximum pressure is 150 psi water and 35 psi steam. Tapped 1" female
I.P.
|
|
51-2M
|
Combination
float type low water cutoff & water feeder, for low pressure steam
or hot water boilers larger than 5,000 square feet capacity. Manual
reset on 120 volt number 2 cutoff switch, continuous maintenance
of minimum safe water level independent of electrical service.
Maximum pressure is 150 psi water and 35 psi steam. Tapped 1" female
I.P.
|