| SSSparts.com is
a distributor for Fireye. Our company has been
supplying parts to the HVAC industry for over 30 years. Our experienced
staff has completed many HVAC programs and can answer many technical
questions if you need assistance choosing your part. Just call
us toll free at 1-800-338-0236 to
speak with a representative directly at our warehouse, or Contact Us,
and we will be happy to help you find the parts you need.
Our full time staff is available Monday – Friday 8:00 am -
4:00 pm EST to take your order, or to help you with choosing your
parts. |
|
| Flame-Monitor™ A
microprocessor-based flame safeguard programming control offering
2-line LCD alpha-numeric display (ED510) with local access to burner
history, or LED indicator lights (EPD Programmers), modular design
and communication capability. |
| Chassis
and Display |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| E100 |
Replace
with E110 & ED510 |
— |
— |
| E110 |
Control, consisting
of EB700, 48-1836, EC600. 120 VAC. Display ordered separately. UL,
FM, UL/c Approved. |
3 |
E-1101 |
| E120 |
Same as E110 except
220 VAC, consisting of EB701, 48-1836, EC600. 220 VAC. FM Approval
only. |
20 |
E-1201 |
| E200 |
Control, consisting
of ED500, EB720, 48-1805, EC600. 220 VAC. Use with EP113 only. CE
Approved. |
— |
— |
| E201 |
Control, consisting
of ED500, EB721, 48-1805, EC600. 110 VAC. Use with EP113 only. CE
Approved. |
— |
— |
| E210 |
Control, consisting
of EB720, 48-1836, EC600. 220 VAC. Use with EP113 only. Display ordered
separately. CE Approved. |
20 |
E-2101 |
| E211 |
Control, consisting
of EB721, 48-1836, EC600. 110 VAC. Use with EP113 only. Display ordered
separately. CE Approved. |
20 |
E-2101 |
|
| Display |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| ED510 |
2
line x 16 character backlit LCD display with keypad. |
3 |
ED-5101 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| EP
Programmers |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| EP113E |
Programmer. Selectable
pre-purge, non-recycle. For use with E200/E210/E201/E211 only. Messages
in English. CE Approved. |
20 |
E-2101 |
| EP113NR |
Programmer.
Non-recycle operation only. Selectable pre-purge. Australian Gas
approval. For use with E200/E210/E201/E211 only. Messages in English.
CE Approved. |
20 |
E-2101 |
| EP160 |
Programmer. Selectable
purge (30 sec min.), 10 and 15 sec. TFI, non-recycle. |
3 |
EP-1601 |
| EP161 |
Programmer. Selectable
purge (30 sec min.), 10 and 30 sec. TFI, non-recycle. |
3 |
EP-1601 |
| EP163 |
Programmer. Selectable
purge, (30 sec min.), selectable TFI via ED510 display, non-recycle. |
20 |
EP-1601 |
| EP165 |
Programmer. Selectable
purge (30 sec min.), pilot stabilization, non-recycle, 10 and 10
sec TFI. |
20 |
EP-1601 |
| EP166 |
Programmer. Selectable
purge (30 sec min.), pilot stabilization, non-recycle, 10 and 15
sec TFI programmer. |
20 |
EP-1601 |
| EP170 |
Programmer. Selectable
purge (30 sec min.), 5 and 10 sec. TFI, non-recycle, early spark
termination. |
3 |
EP-1601 |
| EP174 |
Programmer. Selectable
purge (30 sec min.), 5 and 10 sec. TFI, non-recycle, early spark termination.
M-D circuit must be proven through the completion of MTFI. |
20 |
EP-1601 |
| EP177 |
Programmer. Early
spark termination. ED510 to select purge (30 sec min.), prove air
flow, prove high fire, prove low fire, and post purge. Early spark
termination. Infinite hold on M-D circuit. |
20 |
133-666 |
| EP260 |
Programmer. Selectable
purge (30 sec min.), 10 and 15 sec. TFI, recycle. |
3 |
EP-2601 |
| EP265 |
Programmer. Selectable
purge, (30 sec min.), pilot stabilzation, recycle, 10 and 10 sec
TFI. |
20 |
EP-2601 |
| EP270 |
Programmer. Selectable
purge (30 sec min.), 5 and 10 sec. TFI, recycle, early spark termination. |
20 |
EP-2601 |
| EP380 |
Programmer. Selectable
purge (30 sec min.), 5 and 10 sec TFI, selectable recycle/non-recycle,
no modulation. |
3 |
EP-3801 |
| EP381 |
Programmer. Selectable
purge (15 sec min.), 5 and 10 sec TFI, selectable recycle/non-recycle,
no modulation. |
20 |
EP-3801 |
| EP382 |
Programmer. Selectable
purge (0 sec min.), 5 and 10 sec TFI, selectable recycle/non-recycle,
no modulation. |
20 |
EP-3801 |
| EP383 |
Programmer. Selectable
purge, selectable TFI, selectable recycle/non-recycle via ED510,
no modulation, no agency approvals. |
20 |
EP-3801 |
| EP387 |
Programmer. Selectable
purge (15 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle,
no modulation, Infinite hold on M-D circuit. |
20 |
EP-3801 |
| EP390 |
Programmer. Selectable
purge (90 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle,
no modulation. |
20 |
EP-3801 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| EPD
Programmers (with built-in LED indicator lights) |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| EPD160 |
Programmer.
30 sec purge, 10 and 15 sec TFI, non-recycle. |
20 |
EPD-1601 |
| EPD161 |
Programmer, 30
sec purge, 10 ad 30 sec TFI, non-recycle. |
CF |
EPD-1601 |
| EPD167 |
Programmer. 30
sec prurge, 10 and 15 sec TFI, non-recycle. Infinite hold on M-D
circuit. |
20 |
EPD-1601 |
| EPD170 |
Programmer. 30
sec purge, 5 and 10 sec TFI, non-recycle, early spark termination. |
20 |
EPD-1601 |
| EPD260 |
Programmer. 30
sec purge, 10 and 15 sec TFI, recycle. |
20 |
EPD-2601 |
| EPD261 |
Programmer. 30
sec purge, 10 and 30 sec TFI, recycle. |
CF |
EPD-2601 |
| EPD270 |
Programmer. 30
sec purge, 5 and 10 sec TFI, recycle, early spark termination. |
CF |
EPD-2601 |
| EPD380 |
Programmer. 30
sec purge, 5 and 10 sec TFI, recycle, no modulation. |
20 |
EPD-3801 |
| EPD381 |
Programmer. 15
sec purge, 5 and 10 sec TFI, recycle, no modulation. |
CF |
EPD-3801 |
| EPD382 |
Programmer. 0
sec purge, 5 and 10 sec TFI, recycle, no modulaton. |
CF |
EPD-3801 |
| EPD390 |
Programmer. 90
sec purge, 5 and 10 sec TFI, recycle, no modulation. |
20 |
EPD-3801 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| Flame
Amplifiers |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| E1R1 |
Infrared
autocheck amplifier, use with 48PT2. |
3 |
EAMP1 |
| E1R2 |
Infrared autocheck
amplifier, use with 48PT2. Special appllication only, consult factory. |
20 |
EAMP1 |
| E1R3 |
Infrared autocheck
amplifier, use with 48PT2. Solid fuels only. |
20 |
EAMP1 |
| ERT1 |
Flame rectification
amplifier, use with 45CM or 69ND. |
3 |
EAMP1 |
| EUV1 |
Ultraviolet amplifier,
use with UV1, UV2, UV8, UV90, or 45UV3. |
3 |
EAMP1 |
| EUVS4 |
Ultraviolet self
check amplifier. Use with 45UV5-1005, -1007, -1008, -1009, or 55UV5-1007,
-1009 |
3 |
EAMP1 |
|
| Programmers
& Flame Amplifiers for Use with Integrated Flame Scanners |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| EP178 |
Programmer.
Keypad adjustable purge time, PTFI time, MTFI time, post purge time,
early spark termination, pilot proving period, and indefinite hold
on low fire start. For use with EDC1 and EDC2 amplifiers and 85UVF4-1WR
flame scanner.. |
20 |
133-674 |
| EP378 |
Programmer. Keypad
adjustable purge time, PTFI time, MTFI time, post purge time, early
spark termination, pilot proving period, and indefinite hold on low
fire start. No modulation. For use with EDC1 and EDC2 amplifiers
and 85UVF4-1WR.. |
20 |
133-674 |
| EDC1 |
Amplifier, for
use with EP178 / EP378 and one or two 85UVF4-1WR scanners. |
20 |
133-674 |
| EDC2 |
Amplifier, for
use with EP178 and two 85UVF-41WR scanners to monitor pilot and main.
Scanners automatically switched at appropriate time. |
20 |
133-674 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| E300
Expansion Module |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| E300 |
Expansion
module - use with E100/E110/E201/E211 |
3 |
E-3001 |
| E320 |
Expansion module
- use with E200/E210 or E120 (wire per E110 for E120) |
CF |
E-3201 |
| E350-3 |
Expansion module
cable, 3 ft. length |
3 |
E-3001 |
| E350-6 |
Expansion module
cable, 6 ft. length |
20 |
E-3001 |
| 60-1950 |
Expansion module
wiring base. |
3 |
E-3001 |
|
| E500
Communication Accessories |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| E500-1 |
Communication
interface - single E100/E110 |
20 |
E-5001 |
| E500-3 |
Communication
interface - up to 4 E100's/E110's |
20 |
E-5001 |
| ED550-2 |
E500/remote display
(ED500) cable, 18 inches |
20 |
E-5001 |
| ED550-3 |
E500/remote display
(ED500) cable, 3 feet |
20 |
E-5001 |
| ED550-6 |
E500/remote display
(ED500) cable, 6 feet |
20 |
E-5001 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| Flame-Monitor
Accessories |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| EB500 |
Blank
display module |
20 |
E-8001 |
| EB700 |
Replacement chassis
for E100/E110 |
3 |
E-1101 |
| EB701 |
Replacement chassis
for E120. 120 VAC. FM Approval only |
CF |
E-1201 |
| EB720 |
Replacement chassis
for E200/E201 |
20 |
E-2101 |
| EB721 |
Replacement chassis
for E201/211 |
20 |
E-5001 |
| EC485 |
RS232/RS485 converter
with power supply and FJ12 jack |
20 |
EC-4851 |
| EC600 |
Red dust cover
for E100/E110/E120/E200/E201/E210/E211 |
20 |
E-1101 |
| EC601 |
High shock dust
cover kit used with 60-1915 high shock wiring base |
CF |
- |
| ED150-3 |
Remote reset cable,
3 feet |
3 |
E-8001 |
| ED150-6 |
Remote reset cable,
6 feet |
20 |
E-8001 |
| ED150-15 |
Remote reset cable,
15 feet |
20 |
E-8001 |
| ED150-25 |
Remote reset cable,
25 feet |
CF |
E-8001 |
| ED400 |
Remote display
housing (ED500) |
CF |
E-8001 |
| ED512-2 |
RJ12 connector
cable - 2 feet |
3 |
E-8002 |
| ED512-4 |
RJ12 connector
cable - 4 feet |
3 |
E-8002 |
| ED512-8 |
RJ12 connector
cable - 8 feet |
20 |
E-8002 |
| ED580-1 |
ED510 remote display
cable with RJ45 connector - 1 1/4 inch |
20 |
ED-5101 |
| ED580-2 |
ED510 remote display
cable with RJ45 connector - 2 feet |
20 |
E-8002 |
| ED580-4 |
ED510 remote display
cable with RJ45 connector - 4 feet |
20 |
E-8002 |
| ED580-8 |
ED510 remote display
cable with RJ45 connector - 8 feet |
20 |
E-8002 |
| ED600 |
Multi-port cable
adaptor for E100 accessories |
20 |
E-8001 |
| ED610 |
Multi-port cable
adaptor for E110 accessories |
3 |
E-8002 |
| ED611 |
Multi-port cable
adaptor for E110 accessories without ED510 reset |
CF |
E-8002 |
| ED612 |
Packaged with
EC485, IC485 and UC485. PCB with RJ12 telephone jack |
CF |
- |
| UC485 |
USB RS232/RS485
converter |
20 |
- |
| 14-64 |
Schaffner Noise
Filter |
CF |
- |
| 33-426 |
Captive nut for
wiring base (60-1386, 60-1466) |
20 |
- |
| 48-1805 |
Mounting screw
for E100, E200, E340, 25SU5-5011, -5166 |
20 |
- |
| 48-1836 |
Mounting screw
for E110, E210, E211, E120 |
20 |
- |
| 57AV4-5001 |
Tester, 120 VAC,
for use with C, D-Series and Flame Monitor |
CF |
CP-47 |
| 60-1386-2 |
Closed wiring
base for surface mtg., use with D Series and Flame Monitor. |
3 |
D-1020
E-1101
|
| 60-1466-2 |
Open wiring base
for cabinet metgl, use with D Series and Flame Monitor |
3 |
D-1020
E-1101 |
| 60-1915 |
High shock wiring
base for D-Series and Flame Monitor |
CF |
- |
| 60-2107 |
Service adaptor,
wiring base with access to terminals |
CF |
SA-1027 |
| 60-2333 |
Noise filter.
Obsolete. Replaced by 14-64 |
- |
- |
| 61-4016 |
Flame simulator
(UV, IR, Flame rod) for 57AV4-5001 |
CF |
- |
| 129-145-1 |
Remote display
(ED510) mounting kit with 4' cable |
3 |
E-8002 |
| 129-145-2 |
Remote display
(ED510) mounting kit with 8' cable |
3 |
E-8002 |
| 129-145-3 |
Remote display
(ED510) mounting kit with 2' cable |
20 |
E-8002 |
| 129-152 |
Ferrite core for
ED512/ED580 cables |
CF |
E-8002 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| M
- Series II |
| Chassis |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| MC120 |
120
VAC, 50/60 Hz Chassis |
3 |
C-4000 |
| MC120E |
120 VAC, 50/60
Hz Chassis. Meets European EN230, EN298 approval |
20 |
C-4000 |
| MC120P |
120 VAC, 50/60
Hz Chassis with remote reset and post purge |
20 |
C-4000 |
| MC120R |
120 VAC, 50/60
Hz Chassis with remote reset |
3 |
C-4000 |
| MC120RE |
120 VAC, 50/60
Hz Chassis with remote reset. Meets European EN230, EN298 approval |
CF |
C-4000 |
| MC230 |
230 VAC Chassis.
Meets European EN230, EN298 approval |
3 |
C-4000 |
| MC230R |
230 VAC Chassis
with remote reset. Meets European EN230, EN298 approval |
3 |
C-4000 |
|
| Programmer
Modules |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| MP100 |
Programmer,
Relight function |
3 |
C-4001 |
| MP100E |
Programmer, Relight
function. For MC230, MC120E only |
3 |
C-4001 |
| MP101 |
Programmer, Rellight
function. Will ignore flame signal during off cycle |
3 |
C-4001 |
| MP102 |
Programmer, 5
sec TFI, lockout on flame failure |
20 |
C-4001 |
| MP102E |
Programmer, 5
sec TFI, lockout on flame failure. For MC230 only |
20 |
C-4001 |
| MP230 |
Programmer, Selectable
recycle/non-recycle function, TFI, and purge timing |
3 |
C-4001 |
| MP230H |
Programmer, Selectable
recycle/non-recycle function, TFI, and purge timing. Pilot stabilization,
two stage capability |
3 |
C-4001 |
| MP560 |
Programmer, Selectable
recycle/non-recycle function, TFI, and purge timing. Pilot cutoff,
pilot stabilization, check-run switch. |
3 |
C-4001 |
| MP561 |
Programmer, Selectable
recycle/non-recycle function, TFI, and purge timing. Pilot cutoff,
check-run switch. |
3 |
C-4001 |
| MP562 |
Programmer, Selectable
TFI, and purge timing. Pilot cutoff, pilot stabilization, lockout
on loss of air flow, non-recycle, check-run switch |
20 |
C-4001 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| Amplifier
Modules |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| MAUV1 |
UV
amp, 2-4 sec FFRT. Use with UV1, UV2, 45UV3 |
3 |
C-4002 |
| MAUV1T |
UV amp, .8 sec
FFRT. Use with UV1, UV2, 45UV3 |
3 |
C-4002 |
| MAUV3 |
UV amp, 3 sec
FFRT. Use with UV1, UV2, 45UV3 |
CF |
C-4002 |
| MART1 |
Flame rect amp,
2-4 sec FFRT. Use with 69ND, 45CM |
3 |
C-4002 |
| MART1T |
Flame rect amp,
.8 sec FFRT. Use with 69ND, 45CM |
3 |
C-4002 |
| MART3 |
Flame rect amp.
3 sec FFRT. Use with 69ND, 45CM |
CF |
C-4002 |
|
| Accessories |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| 23-176 |
Replaceable
fuse for M-Series II programmer modules. Littlefuse 22508, 2 AG,
8 amp, 125 V |
3 |
- |
| 23-183 |
Replaceable fuse
for MP100E programmer module. Littlefuse 22903.5, 3.5 amp, 250 V |
20 |
- |
| 57AV7-1000 |
Tester, 120 VAC,
for use with M-Series II, MicroM |
20 |
C90 |
| 60-1764 |
Obsolete - MM-1
adapter to replace RA890 with M-Series II, MicroM |
- |
- |
| 60-1765 |
MM-2 adapter to
replace R4795 with M-Series II, MicroM |
CF |
MM-2 |
| 61-3060 |
Closed wiring
base for surface mtg., use with M-Series II and MicroM |
3 |
MC-5000 |
| 61-5042 |
Open wiring base
for cabinet mtg., use with M-Series II and MicroM |
3 |
MC-5000 |
|
| Flame
Scanners |
| Ultra
Violet Scanners |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| UV1A3 |
UV
scanner, 1/2" NPT connector, 3 ft. flex conduit (900 mm) |
3 |
SC-102 |
| UV1A6 |
UV scanner, 1/2"
NPT connector, 6 ft. flex conduit (1800 mm) |
3 |
SC-102 |
| UV1A8 |
UV scanner, 1/2"
NPT connector, 8 ft. flex conduit (2400 mm) |
20 |
SC-102 |
| UV1A12 |
UV scanner, 1/2"
NPT connector, 12 ft. flex conduit (3600 mm) |
3 |
SC-102 |
| UV1AC20 |
UV scanner, 1/2"
NPT connector, axial mount, 20 foot cable (6100 mm), no flex conduit |
CF |
SC-102 |
| UV1A50 |
UV scanner, 1/2"
NPT connector, 50 ft. flex conduit |
CF |
SC-102 |
| UV2 |
UV scanner, 3/8"
NPT connector, 3 ft. flex conduit (900 mm) |
3 |
SC-102 |
| UV2C |
UV scanner, 1/2" NPT
connector, 3 ft. no armor flex |
20 |
SC-102 |
| UV8A |
UV scanner, 1/2"
NPT connector, 90 degreee angle head, 6 ft. cable, no armor flex. |
3 |
SC-102 |
| UV8A20 |
UV scanner, 1/2"
NPT connector, 90 degree angle head, 20 ft. cable, no armor flex. |
CF |
SC-102 |
| UV90-3 |
UV non-self check
scanner for frontal or side (90 degree) viewing. Complete with mounting
fixture and 3 foot flex conduit (900 mm) |
CF |
SC-102 |
| UV90-6 |
UV non-self check
scanner for frontal or side (90 degree) viewing. Complete with mounting
fixture and 6 foot flex conduit (1800 mm) |
CF |
SC-102 |
| UV90-9 |
UV non-self check
scanner for frontal or side (90 degree) viewing. Complete with mounting
fixture and 9 foot flex conduit (2700 mm) |
CF |
SC-102 |
| 45UV2-1020 |
Obsolete - UV
scanner, 1" NPT, 8' leads, 60 Hz, use with P-Series |
CF |
- |
| 45UV3-1050 |
UV scanner, 3/4"
mount, 4-314-1 UV tube |
20 |
SC-102 |
| 45UV5-1005 |
UV self-check
scanner, 1" NPT, 8' lead, use with P-Series or MicroM/E-Series with
61-5745-3 drive circuit |
3 |
SC-101 |
| 45UV5-1105 |
UV self-check
scanner, 1" BSP, 8' lead, use with P-Series |
CF |
SC-101 |
| 45UV5-1006 |
UV self-check
scanner, 8' lead, use with D-Series 72DUVS1 |
CF |
SC-101 |
| 45UV5-1007 |
UV self-check
scanner, 1" BSP, 230 VAC shutter. Use with 72DUVS1T, 72DUVS4 EUVS4,
MicroM, FlameWorx II.. |
3 |
SC-101 |
| 45UV5-1007W |
See 55UV5-1007 |
- |
Obsolete |
| 45UV5-1008 |
UV self-check
scanner, 1" BSP, 120 VAC shutter. Use with 72DUVS4, 72DUVS1T, or
EUVS4 |
20 |
SC-101 |
| 45UV5-1009 |
UV self-check
scanner, 1" NPT, 120 VAC shutter. Use with 72DUVS4, 72DUVS1T,
EUVS4, MicroM, FlameWorx II |
3 |
SC-101 |
| 45UV5-1009W |
See 55UV-1009 |
CF |
Obsolete |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| Infrared
Scanners |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| 48PT2-1003 |
Infrared
scanner, 8', straight head, D-Series, E-Series, MicroM |
3 |
SC-103 |
| 48PT2-1007 |
Infrared scanner,
4', straight head, D-Series, E-Series, MicroM |
3 |
SC-103 |
| 48PT2-9003 |
Infrared scanner,
8', 90 degree head, D-Series, E-Series, MicroM |
3 |
SC-103 |
| 48PT2-9007 |
Infrared scanner,
4', 90 degree head, D-Series, E-Series, MicroM |
3 |
SC-103 |
| 48PT2-9007W |
Infrared scanner,
4', 90 degree head, water resistant, D-Series, E-Series, MicroM |
20 |
SC-103 |
|
| Explosion-Proof
Scanners |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| UV1A-1-CEX |
Cenelec
EExd IIC explosion proof housing with UV1A scanner |
CF |
SC-102 |
| UV1A6-EX |
NEMA 7, Class
1, Div 1 and 2, Groups C and D; Class 2, Div 1 and 2, Groups E, F,
and G housing with UV1A6 scanner. |
20 |
SC-102 |
| UV1A50-EX |
NEMA 7, Class
1, Div 1 and 2, Groups C and D; Class 2, Div 1 and 2, Groups E, F,
and G housing with UV1A50 scanner. |
CF |
SC-102 |
| 45UV5-1005CEX |
Cenelec EExd IIC
explosion proof housing with 45UV5-1005 scanner |
CF |
SC-101 |
| 45UV5-1005EX |
NEMA 7, Class
1, Div 1 and 2, Groups C and D; Class 2, Div 1 and 2, Groups E, F,
and G housing with 45UV5-1005 scanner |
CF |
SC-101 |
| 45UV5-1007CEX |
Cenelec EExd IIC
explosion proof housing with 45UV5-1007 scanner |
CF |
SC-101 |
| 45UV5-1007EX |
See 55UV5-1007 |
- |
Obsolete |
| 45UV5-1009CEX |
Cenelec EExd IIC
explosion proof housing with 45UV5-1009 scanner |
CF |
SC-101 |
| 45UV5-1009EX |
See 55UV5-1009 |
- |
Obsolete |
| 48PT2-CEX |
Cenelec EExd IIC
explosion proof housing with 48PT2 scanner |
CF |
SC-103 |
| 55UV5-1007 |
UV self-check
scanner. Meets Class 1, Div 2, Groups A, B, C, and D, NEMA 4X. 1"
BSP, 102-260 VAC, 50/60 Hz |
CF |
SC-106 |
| 55UV5-1009 |
UV self-check
scanner. Meets Class 1, Div 2, Groups A, B, C, and D, NEMA 4X. 1" NPT,
102-260 VAC, 50/60 Hz |
CF |
SC-106 |
| Call 1-800-338-0236 Mon-Fri 8:00
a.m. - 4:00 p.m. EST if you have any questions, or to place an order. |
|
| Flame
Rods |
| Part
Number |
Description |
Lead
Time |
Bulletin
Number |
| 69ND1-1000K4 |
Flame
rod, 12", 1/2" mount (Auburn P/N FRS-2-12) |
3 |
SC-103 |
| 69ND1-1000K6 |
Flame rod, 18",
1/2" mount (Auburn P/N FRS-2-18) |
20 |
SC-103 |
| 69ND1-1000K8 |
Flame rod, 24",
1/2" mount (Auburn P/N FRS-2-24) |
20 |
SC-103 |
| 48PT2-9007 |
Infrared scanner,
4', 90 degree head, D-Series, E-Series, MicroM |
3 |
SC-103 |
|
| |